Rockwell Automation Publication 280E-UM001B-EN-P - July 2012 199
Bulletin 280E/281E/284E Programmable Parameters Chapter 7
191 PWM Frequency
Sets the carrier frequency the PWM output waveform.
Figure72 provides derating guidelines based on the PWM
frequency setting.
4.0 Hz Drive Advanced Setup
192 Auto Rstrt Tries
Set the maximum number of times the drive attempts to reset a
fault and restart.
0 Drive Advanced Setup
193 Auto Rstrt Delay
Sets time between restart attempts when Parameter 192 (Auto
Rstrt Tries) is set to a value other than zero.
1.0 Secs Drive Advanced Setup
194 Start At PowerUp
Enables/disables a feature that allows a Start or Run command to
automatically cause the drive to resume running at command
speed after the drive input is restored.
0 = Disabled Drive Advanced Setup
195 Reverse Disable
Enables/disables the function that allows the direction of the
motor rotation to be changed.
0 = Disabled Drive Advanced Setup
196 Flying Start En
Sets the condition that allows the drive to reconnect to a spinning
motor at actual RPM.
0 = Disabled Drive Advanced Setup
197 Compensation
Enables/disables correction options that may improve problems
with motor instability.
1 = Electrical Drive Advanced Setup
198 SW Current Trip
Enables/disables a software instantaneous (within 100 ms)
current trip.
0.0 (Disabled) Drive Advanced Setup
199 Process Factor
Scales the output frequency value displayed by Parameter 110
(Process Display).
30.0 Drive Advanced Setup
200 Fault Clear
Resets a fault and clears the fault queue.
0 = Ready/Idle Drive Advanced Setup
201 Program Lock
Protects parameters against change by unauthorized personnel.
0 = Unlocked Drive Advanced Setup
202 Testpoint Sel
Used by Rockwell Automation field service personnel.
400 Drive Advanced Setup
203 Option not valid for Bulletin 284E ArmorStart.
204 Option not valid for Bulletin 284E ArmorStart.
205 Comm Loss Action
Selects the drive’s response to a loss of the communication
connection or excessive communication errors.
0 = Fault Drive Advanced Setup
206 Comm Loss Time
Sets the time that the drive remain in communication loss before
implanting the option selected in Parameter 205 (Comm Loss
Action).
15.0 Secs Drive Advanced Setup
207 Option not valid for Bulletin 284E ArmorStart.
208 Option not valid for Bulletin 284E ArmorStart.
209 Option not valid for Bulletin 284E ArmorStart.
210 Option not valid for Bulletin 284E ArmorStart.
211 Option not valid for Bulletin 284E ArmorStart.
212 Option not valid for Bulletin 284E ArmorStart.
213 Option not valid for Bulletin 284E ArmorStart.
214 Slip Hertz @ FLA
Compensates for the inherent slip in an induction motor. This
frequency is added to the commanded output frequency based
on motor current.
2.0 Hz Drive Advanced Setup
Table 29 - Parameter Descriptions
Parameter
Number
Parameter
Name
Description Factory Default Group
Vedere la pagina 198
1 2 ... 194 195 196 197 198 199 200 201 202 203 204 ... 347 348

Commenti su questo manuale