1–5Getting Started
1336 FORCE — 5.9 August 1995
4. Enter the minimum value by clicking on the Value field for
Node 2 and entering –32765. Press enter to save the value as
shown above.
You have now created the first function block and set the input node
value limits as shown below.
NODE#
BLOCK ID#
Input 1 1:0
Max Val (32765) 1:1
LIMIT
ID # 1
@ Max Lim 1:3
@ Min Lim 1:4
Output 1:5
Min Val (–32765) 1:2
Step 2 — Enter a Set/Reset FF Block
To add a Set Reset FF function block:
1. Move the cursor to the left side of the execution list and click.
2. Select the A
dd Block option from the Function Blocks
pull-down menu.
3. Double click on Set Reset FF — [Lib ID: 22].
4. Click on Close.
As shown below, the DriveBlockEditor software now enters a Set
Reset Flip Flop function block and gives it an ID # of 2.