Publication 2092-RM001A-EN-P — March 2005
Command Reference 2-31
[Pr – 4.05] Overtravel Current Limit
[Pr – 4.06] Initial Current Bias
Ultraware Name:
Stopping Functions: Maximum Stopping Current
Range: 0 to 500
Default:
500
Units: % of rated continuous current
Operating Mode: All
Description:
Constant current applied when the drive enables.
This command is intended to hold vertical loads.
Range: -100 to 100
Default: 0
Units: % of motor rated continuous current
Operating Mode: All