Command Reference 2-21
Group 1 Parameters
[Pr – 1.01] Velocity Regulator P-Gain
[Pr – 1.02] Velocity Regulator I-Gain
[Pr – 1.03] Position Regulator Kp-Gain
[Pr – 1.04] Current Command Low Pass Filter Bandwidth
[Pr – 1.05] Velocity Command Low Pass Filter Bandwidth
Ultraware Name: Main Velocity Regulator Gains: P
Range: 0 to 500
Default: 60
Operating Mode: Follower, Analog Velocity, Preset
Ultraware Name: Main Velocity Regulator Gains: Integrator Time
Range: 0 to 60000
Default: 26
Operating Mode: Follower, Analog Velocity, Preset
Ultraware Name: Main Position Regulator Gains: Kp
Range: 0 to 700
Default: 20
Units: Hz
Operating Mode: Follower
Ultraware Name: Main Current Regulator Gains: Low Pass Filter Bandwidth
Range: 0 to 10000
Default: 300
Units: Hz
Operating Mode: All
Ultraware Name: Main Velocity Regulator Gains: Low Pass Filter Bandwidth
Range: 0 to 10000
Default: 1000
Units: Hz
Operating Mode: Follower, Analog Velocity, Preset