Chapter 3 Force steps
For example, to exit this branch, the SFC
must be able to complete these actions.
Execute Step_011 at least once
Get past Tran_011 and execute
Step_012 at least once
Determine that Tran_012 is TRUE
Force a simultaneous path
To prevent the execution of a path of a simultaneous branch, force the path
FALSE. When the SFC reaches the branch, it executes only the un-forced paths.