5–7OCI Data Server CNC Commands
Publication 8520-6.6 - August 1999
TRANSFER_HOMECAL_TO_PORTB (no argument)
Use this command to send the current home calibration data to a
printer or other device connected to the control’s port B
. This will
print the home calibration data currently in RAM. This may or may
not be the same home calibration data stored in the control’s flash
memory.
For example:
[TRANSFER_HOMECAL_TO_PORTB]
prints the home calibration data to the device connected to the
control’s port B. You can only use this command to output home
calibration data to a printer.
Important: This command does not apply to the 9/PC CNC.
TRANSFER_REVERSAL_ERROR_TO_PORTA (no argument)
Use this command to send the current reversal error data to a printer
or other device connected to the control’s port A
. This will print the
reversal error compensation data currently in RAM. This may or
may not be the same data stored in the control’s flash memory.
For example:
[TRANSFER_REVERSAL_ERROR_TO_PORTA]
prints the reversal error data to the device connected to the control’s
port A. You can only use this command to output reversal error data
to a printer.
Important: This command does not apply to the 9/PC CNC.