Data
Types
Chapter 7
7–3
Figure
7.3
T
runcated 4-Digit BCD Integer
This value requires one word of the processor data table. The data is
represented by a 4-digit octal integer (figure 7.4). The value ranges from
"7777 8 ("4095). Overflow, underflow and sign are also indicated. If an
overflow or underflow condition exists, the appropriate bit is set and the
value of 0000 is reported. Fractional portions of any number used in this
routine are truncated.
Figure
7.4
T
runcated 4-Digit Octal Integer
7.2.3
4-digit, Unsigned,
Fixed Decimal BCD
(continued)
7.2.4
4-digit, Signed, Octal
Vedere la pagina 144