Chapter 1 Manage tasks
EXAMPLE
If Condition_1 = 0 then let Task_2 run.
1. The ONS instruction limits the true run of the SSV instruction to one scan.
2. The SSV instruction sets the InhibitTask attribute of Task_2 = 0. This uninhibits the task.
If Condition_1 = 1 then do not let Task_2 run.
1. The ONS instruction limits the true run of the SSV instruction to one scan.
2. The SSV instruction sets the InhibitTask attribute of Task_2 = 1. This inhibits the task.
Follow these steps to create an event task.
1. In the Controller Organizer, right-click the Tasks folder and choose New
Task.
Create a task
26 Rockwell Automation Publication 1756-PM005-EN-P - October 2014