Rockwell Automation Publication IASIMP-QS026A-EN-P - July 2012 31
Create DeviceNet Network Software Files Chapter 3
4. Record the following information
about the 1769-SDN scanner
module:
Slot number in the
CompactBus = 1
DeviceNet network node number = 1
5. Click OK.
6. Click OK when the alert about
uploading or downloading device
information.
RSNetWorx for DeviceNet
software browses the network and
shows the scanner module at
DeviceNet network node number
1 and the 1734-ADN adapter at
node number 2.
TIP
Once the software browses
the DeviceNet network to
recognize the two nodes
installed while completing
the tasks described in this
quick start, you can click
Cancel and the browse
function ends.
Slot number = 1
DeviceNet network
node number = 1
Vedere la pagina 30