Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manuale Utente Pagina 132

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 176
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 131
Publication 2098-RM003A-EN-P October 2001
2-116 Command Reference
Current Feedback
U-Phase Current
W-Phase Current
Motor Temperature
Format: :aa08Dfddddcc<cr>
Parameter
Code:
0x08D
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddd Current feedback, in units of Amps*128.
Format: :aa08Efddddcc<cr>
Parameter
Code:
0x08E
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddd U-phase current feedback, in units of Amps*128.
Format: :aa08Ffddddcc<cr>
Parameter
Code:
0x08F
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddd W-phase current feedback, in units of Amps*128.
Format: :aa092fddddcc<cr>
Parameter
Code:
0x092
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddd Motor temperature, in units of percent*128.
Vedere la pagina 131
1 2 ... 127 128 129 130 131 132 133 134 135 136 137 ... 175 176

Commenti su questo manuale

Nessun commento