Shaded bit positions must be set to 0. Entering a binary value greater than 100000 (greater than 32 decimal) results in a
configuration error.
Darker shaded bit positions must be set to 0.
Inverted
Virtual
Input 7
1 0 0 0 0 0
Word
Bit Position
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
12,
20,
28,
36
Operator_
1_0
Operator_
1_1
Operator_
1_2
Operator_
1_3
None 0 0
OR 0 1
AND 1 0
XOR 1 1
Operator_
2_0
Operator_
2_1
Operator_
2_2
Operator_
2_3
None 0 0
OR 0 1
AND 1 0
XOR 1 1
Word
Bit Position
1514131211109876543210
Vedere la pagina 18