Rockwell-automation 1769-BOOLEAN Compact I/O BOOLEAN Module Installati Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Apparecchiature Rockwell-automation 1769-BOOLEAN Compact I/O BOOLEAN Module Installati. Rockwell Automation 1769-BOOLEAN Compact I/O BOOLEAN Module Installation Instructions User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Publication 1769-IN077A-EN-P - May 2006
Installation Instructions
Compact Combination 24V dc Sink Input/Source
Output BOOLEAN Control Module
Catalog Number 1769-BOOLEAN
Inside . . .
About This Publication
Use this document as a guide when installing a Compact Combination 24V dc Sink
Input/Source Output BOOLEAN Control Module.
For See Page
About This Publication 1
About the 1769-BOOLEAN Module 5
Module Description 5
Install the 1769-BOOLEAN Module 6
Replace a Single Module Within a System 7
Mount Expansion I/O 8
Minimum Spacing 8
Mount Module to Panel 8
Wire the 1769-BOOLEAN Module 10
Ground the 1769-BOOLEAN Module 11
Configure the 1769-BOOLEAN Module 12
Specifications 22
Additional Resources 27
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - Output BOOLEAN Control Module

Publication 1769-IN077A-EN-P - May 2006Installation InstructionsCompact Combination 24V dc Sink Input/Source Output BOOLEAN Control ModuleCatalog Num

Pagina 2 - Important User Information

10 Publication 1769-IN077A-EN-P - May 2006Wire the 1769-BOOLEAN ModuleEach terminal accepts as many as two wires with these restrictions:Simplifie

Pagina 3 - Remove Power

11Publication 1769-IN077A-EN-P - May 2006Input/Output WiringGround the 1769-BOOLEAN ModuleThis product is intended to be mounted to a well-ground

Pagina 4 - Environnements dangereux

12 Publication 1769-IN077A-EN-P - May 2006Configure the 1769-BOOLEAN ModuleThe following I/O memory mapping lets you configure the 1769-BOOLEAN mo

Pagina 5 - Module Description

13Publication 1769-IN077A-EN-P - May 2006Configuration Data FileThe manipulation of bits from this file is normally done with programming softwar

Pagina 6

14 Publication 1769-IN077A-EN-P - May 2006Shaded bit positions must be set to 0.Input filter: Real input point filter selection. See page 15.EI_Ix

Pagina 7

15Publication 1769-IN077A-EN-P - May 2006IT_Ox: Output interrupt type. See page 16.Operand_A_x: BOOLEAN operand A. See page 17.Operand_B_x: BOOLE

Pagina 8 - Mount Module to Panel

16 Publication 1769-IN077A-EN-P - May 2006Darker shaded bit positions must be set to 0.WordBit Position15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 08, 16,

Pagina 9 - Mount Module to DIN Rail

17Publication 1769-IN077A-EN-P - May 2006WordBit Position15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 09, 10, 11Operand_A_0Operand_B_0Operand_C_0None 0 0

Pagina 10 - Wire the 1769-BOOLEAN Module

18 Publication 1769-IN077A-EN-P - May 2006Inverted Real Input 70 1 0 0 0 0Virtual Input 00 1 0 0 0 1Inverted Virtual Input 00 1 0 0 1 0Virtual Inp

Pagina 11 - Input/Output Wiring

19Publication 1769-IN077A-EN-P - May 2006Shaded bit positions must be set to 0. Entering a binary value greater than 100000 (greater than 32 deci

Pagina 12 - Input Data File

2 Publication 1769-IN077A-EN-P - May 2006Important User InformationSolid state equipment has operational characteristics differing from those of e

Pagina 13 - Configuration Data File

20 Publication 1769-IN077A-EN-P - May 2006Shaded bit positions must be set to 0. Entering a binary value greater than 1111101000 (greater than 100

Pagina 14

21Publication 1769-IN077A-EN-P - May 2006WordBit Position15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 014, 22, 30, 38Output Duration 0None(1)0 0 0 0 0 0 0

Pagina 15

22 Publication 1769-IN077A-EN-P - May 2006SpecificationsCompact I/O - 1769-BOOLEAN General SpecificationsSpecification ValueClosed Loop Time (Digi

Pagina 16

23Publication 1769-IN077A-EN-P - May 2006Off-state Current, Max 1.5 mAOn-state Voltage, Min 10V dcOn-state Current, Min 2.0 mAInrush Current, Max

Pagina 17

24 Publication 1769-IN077A-EN-P - May 2006(3)Sourcing Output - Source describes the current flow between the I/O module and the field device. Sour

Pagina 18

25Publication 1769-IN077A-EN-P - May 2006Temperature DeratingThe area within the curve represents the safe operating range for the module under v

Pagina 19

26 Publication 1769-IN077A-EN-P - May 2006Transistor Output Transient PulsesThe maximum duration of the transient pulse occurs when minimum load i

Pagina 20

27Publication 1769-IN077A-EN-P - May 2006Additional ResourcesIf you would like a manual, you can:• Download a free electronic version from www.ab

Pagina 21

Publication 1769-IN077A-EN-P - May 2006 PN 40071-209-01(1)Copyright © 2006 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.´H&apos

Pagina 22 - Input Specifications

3Publication 1769-IN077A-EN-P - May 2006Prevent Electrostatic DischargeRemove PowerATTENTIONElectrostatic discharge can damage integrated circuit

Pagina 23 - Output Specifications

4 Publication 1769-IN077A-EN-P - May 2006Hazardous Location ConsiderationsThis equipment is suitable for use in Class I, Division 2, Groups A, B,

Pagina 24 - Certifications

5Publication 1769-IN077A-EN-P - May 2006About the 1769-BOOLEAN ModuleCompact I/O is suitable for use in an industrial environment when installed

Pagina 25 - Temperature Derating

6 Publication 1769-IN077A-EN-P - May 2006Install the 1769-BOOLEAN ModuleAttach the module to the controller or an adjacent I/O module before or af

Pagina 26

7Publication 1769-IN077A-EN-P - May 20067. Attach an end-cap terminator (5) to the last module in the system by using the tongue-and-groove slots

Pagina 27 - Additional Resources

8 Publication 1769-IN077A-EN-P - May 2006Mount Expansion I/OMinimum SpacingMaintain spacing from enclosure walls, wireways, or adjacent equipment.

Pagina 28 - ´H',)!¶1<¨

9Publication 1769-IN077A-EN-P - May 2006Mount Module to Panel Using Modules as a TemplateThis procedure lets you use the assembled modules as a t

Commenti su questo manuale

Nessun commento