Inside
Important User Information........................................................................... 2
For More Information ......................................................................................3
Hazardous Location Considerations............................................................. 4
Environnements dangereux.......................................................................... 4
Electrostatic Damage.................................................................................... 5
1746-NI8 Power Requirements..................................................................... 5
Module Location in Chassis.......................................................................... 6
Heat and Noise Considerations.................................................................... 7
Module Installation and Removal.................................................................. 7
Terminal Wiring........................................................................................... 10
Input Devices.............................................................................................. 15
Specifications.............................................................................................. 17
@JO"VTQQE@JO"VTQQE ".".
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - SLC 500™ Analog Input Module

Publication 1746-IN006A-US-PInstallation InstructionsSLC 500™ Analog Input Module(Catalog Number 1746-NI8)Inside…Important User Information...

Pagina 2 - Important User Information

10 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PTerminal WiringThe 1746-NI8 module contains an 18-position, removable terminal

Pagina 3 - For More Information

SLC 500™ Analog Input Module 11Publication 1746-IN006A-US-PWiring Single-Ended InputsThe following diagram shows typical wiring for the 1746

Pagina 4 - Environnements dangereux

12 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PTypical 1746-NI8 Wiring+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-++++Power Supply Conne

Pagina 5 - 1746-NI8 Power Requirements

SLC 500™ Analog Input Module 13Publication 1746-IN006A-US-PWhen wiring single-ended analog input devices to the analog input module, the num

Pagina 6 - Module Location in Chassis

14 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PIMPORTANTThe module does not provide loop power for analog inputs. Use a power

Pagina 7 - Heat and Noise Considerations

SLC 500™ Analog Input Module 15Publication 1746-IN006A-US-PWiring GuidelinesFollow the guidelines below when planning your system wiring.• T

Pagina 8 - Terminal Block Removal

16 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PWiring Input Devices to the 1746-NI8After the analog input module is properly i

Pagina 9 - Module Removal Procedure

SLC 500™ Analog Input Module 17Publication 1746-IN006A-US-PSpecificationsElectrical SpecificationsDescription SpecificationBackplane Current

Pagina 10 - Terminal Wiring

18 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PPhysical SpecificationsEnvironmental SpecificationsDescription SpecificationLED

Pagina 11 - Wiring Single-Ended Inputs

SLC 500™ Analog Input Module 19Publication 1746-IN006A-US-PInput SpecificationsDescription SpecificationType of Input (Selectable) ±10V dc1

Pagina 12 - Typical 1746-NI8 Wiring

2 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PImportant User InformationBecause of the variety of uses for the products descri

Pagina 13 - IMPORTANT

Publication 1746-IN006A-US-P - February 2000 PN 40071-081-01 (A)

Pagina 14

SLC 500™ Analog Input Module 3Publication 1746-IN006A-US-PFor More InformationFor detailed information on planning and installing your syste

Pagina 15 - Input Devices

4 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PHazardous Location ConsiderationsThis equipment is suitable for use in Class I,

Pagina 16 - ATTENTION

SLC 500™ Analog Input Module 5Publication 1746-IN006A-US-PElectrostatic DamageElectrostatic discharge can damage semiconductor devices insid

Pagina 17 - Specifications

6 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PModule Location in ChassisModular Chassis ConsiderationsPlace your 1746-NI8 modu

Pagina 18 - Environmental Specifications

SLC 500™ Analog Input Module 7Publication 1746-IN006A-US-PHeat and Noise ConsiderationsMost applications require installation in an industri

Pagina 19 - Input Specifications

8 SLC 500™ Analog Input Module Publication 1746-IN006A-US-PTerminal Block RemovalTo remove the terminal block: 1. Loosen the two terminal b

Pagina 20

SLC 500™ Analog Input Module 9Publication 1746-IN006A-US-PModule Installation Procedure1. Align the circuit board of the analog input module