Rockwell-automation SD3000 Drive Configuration, Programming Manuale Utente Pagina 67

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 118
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 66
Meter Port 4
1014 UDG Module Meter Port 4 Register Number Register
Hex Value: N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: UDC register number (o-2044) to be mapped to meter port 4.
1015 UDG Module Meter Port 4 Bit Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: Bit number of the UDC register specified in register 1014 that is to be mapped to port 4.
Enter a value of 100 (bit 00) to 115 (bit 15) as required. Enter a value of zero if all of the register’s bits
are to be displayed.
1016 UDG Module Meter Port 4 Maximum Value Register
I
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description: Set this register to the number that will represent
+1
0V. The maximum allowable value
is 32767.
1017 UDG Module Meter Port 4 Minimum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDG Error Code:
N/A
LED:
N/A
Description:
Set this register to the number that will represent
-1
0V.
The minimum allowable value
is -32768.
3-47
Vedere la pagina 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 117 118

Commenti su questo manuale

Nessun commento