Rockwell-automation IASIMP Computer Numerical Control (CNC) Machining Manuale Utente Pagina 252

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 278
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 251
252 Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012
Appendix B Logic Module Customization
Alarm History Faceplate Logic Modification
The alarm history rungs in the application and device module R02_Monitor routines support the HMI alarm
history faceplate.
If your HMI application does not include the alarm history faceplate, then you can remove this logic from the
monitor routine for each module. You can locate the alarm history faceplate logic rungs just below the alarm
history header, in the rung comments.
To remove logic, select alarm history rungs in each R02_Monitor routine of each application and device module
and press the delete key or menu item.
Vedere la pagina 251
1 2 ... 247 248 249 250 251 252 253 254 255 256 257 ... 277 278

Commenti su questo manuale

Nessun commento