15 Run applications on a personal computer
15-5
• • • • •
2. Navigate to the folder containing the application’s .mer file, and then click the file
name.
3. Click Open.
4. To replace the run-time computers communication settings with the application’s
communication settings, click Yes . To keep the run-time computers communication
settings, click No.
You are notified that the application’s FactoryTalk System Directory of users and
security policies will be loaded on this computer. This is the set of users and policies
that have been set up for the application and are contained in the .mer file.
The computers existing FactoryTalk System Directory will be archived, and will be
restored when you stop the application. To turn off this warning, see page 15-16.
5. To continue, click Ye s. To stop loading the application, click No.
If you continue, the application name is shown in the Current application box in the
FactoryTalk View ME Station dialog box.
6. To run the application, click Run Application.
The DEFAULT user is logged in. If a macro is assigned to the DEFAULT user, the
macro runs.
Shut down applications
To shut down an application, use one of these methods
Press a shutdown button in a graphic display.