Rockwell-automation 873P Ultrasonic Single Analog Output Sensors Insta Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Rockwell-automation 873P Ultrasonic Single Analog Output Sensors Insta. Rockwell Automation 873P Ultrasonic Single Analog Output Sensors Installation Instructions User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 4
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Rockwell Automation 873P-IN005A-EN-P—October 2014
Installation Instructions
Ultrasonic Single Analog Output Sensors
Specifications
AV–Analog voltage (0…10V DC) or AI–Analog current (4…20 mA)
Metallic target 100 x 100 mm (3.94 x 3.94 in.)
Metallic target 200 x 200 mm (7.87 x 7.87 in.)
Metalic target 400 x 400 mm (15.75 x 15.75 in.)
Model 873P-D18-400-D4 873P-D18-900-D4 873P-D18-2200-D4 873P-D30-2500-D4 873P-D30-3500-D4 873P-D30-6000-D4
Certifications cULus Listed and CE Marked for all applicable directives
Rated Sensing Distance
50…400 mm
(1.97…15.7 in.)
100…900 mm
(3.94…35.4 in.)
200…2200 mm
(7.87…88.6 in.)
200…2500 mm
(7.87…98.4 in.)
250…3500 mm
(9.87…137.8 in.)
350…6000 mm
(13.8…236.2 in.)
Teachable Sensing Range
100…400 mm
(3.94…15.7 in.)
100…900 mm 200…2200 mm 200…2500 mm 250…3500 mm 350...6000 mm
Blind Zone
0…50 mm
(0…1.97 in.)
0…100 mm
(0…3.94 in.)
0…200 mm 0…200 mm 0…250 mm 0...350mm
Beam Angle ±8° ±7° 14° ±1° 15° ±2°
Sensitivity Adjustment Push button
Linearity <1% of full scale value
Resolution 1 mm (0.04 in.) 2 mm (0.08 in.) 3 mm (0.12 in.) 2 mm (0.08 in.) 4 mm (0.16 in.) 6 mm (0.24 in.)
Accuracy 0.1% of sensing range
Hysteresis <1% of full scale value
Ripple 5%
Current Consumption ≤50 mA
Output Type
AV or AI
Transducer Frequency 300 kHz 200 kHz 150 kHz 112 kHz 75 kHz
Response Time 500 ms 600 ms
Time Delay before Availability ≤900 ms ≤1400 ms
Electrical Protection Polarity reversal, transient noise, short circuit, overload
Minimum Load (analog voltage) 3 kΩ
Maximum Current (analog voltage output) 40 mA
Temperature Range -20…+60° C (-4…+140° F) -20…+70° C (-4…+158° F)
Temperature Compensation Yes
Temperature Drift ±5%
Housing Material Plastic—PBT
Active Head Material Epoxy—glass resin
Ingress Protection Rating IP67 (EN 60529)
Operating Voltage Catalog Numbers
12…30V DC 873P-D30AI-2500-D4, 873P-D30AI-3500-D4, 873P-D30AI-6000-D4
15…30V DC
873P-D18AV-400-D4, 873P-D18AI-400-D4,
873P-D18AV-900-D4, 873P-D18AI-900-D4,
873P-D18AV-2200-D4, 873P-D18AI-2200-D4, 873P-D30AV-2500-
D4, 873P-D30AV-3500-D4, 873P-D30AV-6000-D4
The 873P sensor is a one set point mode with a
maximum sensing range from the factory.
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
IMPORTANT
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - Installation Instructions

Rockwell Automation 873P-IN005A-EN-P—October 2014Installation InstructionsUltrasonic Single Analog Output SensorsSpecifications AV–Analog voltage (0…

Pagina 2 - Window Mode

Rockwell Automation 873P-IN005A-EN-P—October 20142 873P Ultrasonic Single Analog Output SensorsWindow ModeIn this sensing mode, you teach the senso

Pagina 3 - Beam Diagrams

Rockwell Automation 873P-IN005A-EN-P—October 2014873P Ultrasonic Single Analog Output Sensors 3 Green LED indicates that an echo is reflected bac

Pagina 4 - Dimensions [mm (in.)]

Power, Control and Information Solutions HeadquartersAmericas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 4

Commenti su questo manuale