Rockwell-automation 2711P Software Development Kit User Manual Manuale Utente Pagina 40

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 104
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 39
Publication 2711P-UM005A-EN-P - March 2007
40 PanelView Plus CE-Specific Extensions to the WinCE API
If the value of dwTimeout is within the range 50 to 5000, it is taken to
represent the time in milliseconds that elapse before a timeout and
consequential actions occur. The timer is reset to this value and
started, but if the value of dwTimeout is out of range, the timeout
setting is left unmodified, the watchdog is not tagged and
WATCHDOG_TIMEOUT_FAILED is returned.
The resolution of the high priority thread that watches over the
software tags is 50 milliseconds.
Portability:
The RAC6182 does not have a Software Watchdog.
Requirements:
Runs On Version Defined In
PanelView Plus CE All wdapi.h
Vedere la pagina 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 103 104

Commenti su questo manuale