Chapter 7
SLC Application File
7–2
MOV
MOVE
Source 0
Dest N7:0
0
MOV
MOVE
Source 0
Dest N7:1
3
S:1
15
Rung 2:0
Reset the DTAM Plus Advisor registers during the first scan of the SLC 500.
Rung 2:1
This timer drives the SQO instructions once per second.
TON
TIMER ON DELAY
Timer T4:0
Time Base 0.01
Preset 100
Accum 9
T4:0
DN
( EN )
( DN )
SQO
SEQUENCER OUTPUT
File #N10:0
Mask FFFF
Dest N7:22
Control R6:0
Length 40
Position 2
T4:0
DN
( EN )
( DN )
Rung 2:2
This sequencer simulates the gallons value for screen #22 (TANK LEVEL) in the DTAM Plus.
There are 40 decimal values pre-loaded into #N10:0
La
dd
er
Log
ic P
rogram
Vedere la pagina 67