14 PowerFlex® DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board
Step 5: Remove the Power
Traces Board
1. Remove the screws that secure the terminal lugs (if present) and power
and ground wiring to terminals U, V, W, C, D and PE at the bottom of
the drive.
2. Remove the six stand-offs (and the ground wire) from the Power Traces
circuit board.
=
Remove screws
Note: Non-regenerative drive
without terminal lugs shown.
Vedere la pagina 13