Rockwell-automation 1799-D16U16BAGL 16 Input/16 Output Digital and 2 I Manuale Utente Pagina 26

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 32
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 25
26 16 Input/16 Output Digital and 2 Input/2 Output Analog Embedded I/O Boards
Publication 1799-IN011A-EN-P - February 2007
Troubleshoot the I/O Boards
This board has the following indicators:
Board status indicator
Network status indicator
Logic status
Digital I/O state indicators
Analog I/O state indicators
Status Indicators
Board Status Indicator (Labeled MS)
Indication Status
None No power
Green Blinking Green Needs commissioning
Solid Green Device operational
Red Blinking Red Minor fault
Solid Red Critical fault
42567A
P1
P8
P7
P6
P5
DL NSInput LEDs
MS
Analog LEDs Output LEDs
MSD
LSD
Vedere la pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 32

Commenti su questo manuale

Nessun commento