Rockwell-automation 1793-OB16 Flex Integra Output Module Install Inst Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Apparecchiature Rockwell-automation 1793-OB16 Flex Integra Output Module Install Inst. Rockwell Automation 1793-OB16 Flex Integra Output Module Install Inst User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
FLEX I/O and FLEX Integra are trademarks
of Rockwell Automation Publication 1793-5.9 - December 1999
Installation Instructions
FLEX Integra
16 Protected Source Output Module
(Cat. No. 1793-OB16P and -OB16PS)
Module Installation
This module mounts on a DIN rail. It connects to an adapter or another
FLEX I/O or Integra module. Note: If using this module with FLEX I/O
modules, do not mount between FLEX I/O modules. Mount Integra
modules to the right of the FLEX I/O modules. To mount this module:
1. Remove the cover plug (if used) in the male connector of the unit to
which you are connecting this module.
2. Position the module on the 35 x 7.5mm DIN rail A (A-B pt. no.
199-DR1).
3. Rotate the module onto the DIN rail with the top of the rail hooked
under the lip on the rear of the module.
30869-M
A
A
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - FLEX Integra

FLEX I/O and FLEX Integra are trademarks of Rockwell Automation Publication 1793-5.9 - December 1999Installation InstructionsFLEX Integra 16 Protecte

Pagina 2

2 FLEX Integra 16 Protected Source Output Module Publication 1793-5.9 - December 19994. Press down to lock the module on the DIN rail.If the module do

Pagina 3 - Low Voltage Directive

FLEX Integra 16 Protected Source Output Module 3 Publication 1793-5.9 - December 1999European Union Directive ComplianceIf this

Pagina 4 - VVCOM COM

4 FLEX Integra 16 Protected Source Output Module Publication 1793-5.9 - December 1999WiringThis module is available with 2 styles of terminations: 179

Pagina 5 - 1793-OB16P

FLEX Integra 16 Protected Source Output Module 5 Publication 1793-5.9 - December 1999Wiring ConnectionsIndicatorsA = Status indi

Pagina 6

6 FLEX Integra 16 Protected Source Output Module Publication 1793-5.9 - December 1999C-UL and UL Hazardous Location ApprovalApprobation d’utilisation

Pagina 7

FLEX Integra 16 Protected Source Output Module 7 Publication 1793-5.9 - December 1999C-UL and UL Hazardous Location ApprovalAppr

Pagina 8

Publication 1793-5.9 - December 1999 PN 957259-16Supersedes publication 1793-5.9 - September 1999 © (1999) Rockwell International Corporation.Printed

Commenti su questo manuale

Nessun commento