7–16 Communication Commands
Publication
17706.5.16 - October 1996
protected typed file read
Reads data from an open file in a MicroLogix 1000 or an SLC 500
processor.
C
CMD
0F
STS
TNS
R
STS
TNS
CMD
4F
DST SRC
SRC DST
FNC
A7
File
Type
Tag Offset
DATA
Size
Offset is the word offset into the file (low byte, then high byte).
Size is the size of data to read:
For this processor Valid range for Size (in bytes)
MicroLogix 1000 0248
SLC 500, SLC 5/01, SLC 5/02 096
SLC 5/03 SLC 5/04
0225 with internet protocol
SLC 5/03, SLC 5/04
0236 without internet protocol
protected typed file write
Writes data to an open file in a MicroLogix 1000 or an SLC
processor. For MicroLogix 1000 processors, this command can be
used to update the Terminal ID by writing two bytes. (To do this,
size = 02h, the tag = 4176, the offset = 0000, the file type = 90, and
the two bytes of data contain the terminal ID, low byte first.)
C
CMD
0F
STS
TNS
R
STS
TNS
CMD
4F
DST SRC
SRC DST
FNC
AF
File
Type
Tag OffsetSize
Data
EXT
STS
Offset is the word offset into the file (low byte, then high byte).
Size is the size of data to read:
For this processor Valid range for Size (in bytes)
MicroLogix 1000 0241
SLC 500, SLC 5/01, SLC 5/02 089
SLC 5/03 SLC 5/04
0218 with internet protocol
SLC 5/03, SLC 5/04
0229 without internet protocol
MicroLogix
1000
SLC 500
SLC 5/03
SLC 5/04
MicroLogix 1000
SLC 500
SLC 5/03
SLC 5/04