Compact I/O Analog Output Module
Catalog Number
1769-OF4
User Manual
Vedere la pagina 0
1 2 3 4 5 6 ... 75 76

Sommario

Pagina 1 - User Manual

Compact I/O Analog Output ModuleCatalog Number 1769-OF4User Manual

Pagina 2 - Important User Information

10 Publication 1769-UM020A-EN-P - December 2009Chapter 1 OverviewHardware Features1769-OF4 DANGERDo Not Remove RTB Under PowerUnless Area is No

Pagina 3 - Table of Contents

Publication 1769-UM020A-EN-P - December 2009 11Overview Chapter 1System OverviewThe module communicates to the controller through the bus inter

Pagina 4 - Troubleshooting

12 Publication 1769-UM020A-EN-P - December 2009Chapter 1 OverviewThe channel status words are described in the Input Data File on page 31.The c

Pagina 5

13Publication 1769-UM020A-EN-P - December 2009 13Chapter 2Installation and WiringIntroductionGeneral ConsiderationsThe Compact I/O system is suitable

Pagina 6

14 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringHazardous Location ConsiderationsThis equipment is suitable for

Pagina 7 - Publication

Publication 1769-UM020A-EN-P - December 2009 15Installation and Wiring Chapter 2Removing PowerReduce NoiseMost applications require installatio

Pagina 8 - Additional Resources

16 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringAssemble the Compact I/O SystemThe module can be attached to th

Pagina 9 - Overview

Publication 1769-UM020A-EN-P - December 2009 17Installation and Wiring Chapter 26. To allow communication between the controller and module, mo

Pagina 10 - Chapter 1 Overview

18 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringMount to a PanelMount the module to a panel by using two screws

Pagina 11 - Module Operation

Publication 1769-UM020A-EN-P - December 2009 19Installation and Wiring Chapter 26. Attach the modules to the panel by using the mounting screws

Pagina 12

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Pagina 13 - Installation and Wiring

20 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and Wiring4. On the right-side adjacent module, move its bus lever to the

Pagina 14 - ATTENTION

Publication 1769-UM020A-EN-P - December 2009 21Installation and Wiring Chapter 2System Wiring GuidelinesConsider the following when wiring your

Pagina 15 - Removing Power

22 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringEffect of Transducer/Sensor and Cable Length Impedance on Volta

Pagina 16 - Assemble the Compact I/O

Publication 1769-UM020A-EN-P - December 2009 23Installation and Wiring Chapter 2As output impedance (Rs) and/or resistance (DC) of the cable (R

Pagina 17 - Mounting the Module

24 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringWire the Finger-safe Terminal BlockWhen wiring the terminal blo

Pagina 18 - (4.826 in.)

Publication 1769-UM020A-EN-P - December 2009 25Installation and Wiring Chapter 2Wire Size and Terminal Screw TorqueEach terminal accepts up to

Pagina 19 - Within a System

26 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and Wiring3. Strip about 5 mm (3/16 in.) of insulation away to expose the

Pagina 20 - Grounding the Module

Publication 1769-UM020A-EN-P - December 2009 27Installation and Wiring Chapter 2Wiring Analog OutputsATTENTIONAnalog outputs may fluctuate for

Pagina 21 - System Wiring Guidelines

28 Publication 1769-UM020A-EN-P - December 2009Chapter 2 Installation and WiringNotes:

Pagina 22

29Publication 1769-UM020A-EN-P - December 2009 29Chapter 3Module Data, Status, and Channel ConfigurationIntroductionModule AddressingThis memory map s

Pagina 23 - Terminal Block

3Publication 1769-UM020A-EN-P - December 2009 3Table of ContentsPrefaceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 24 - Wire the Finger-safe

30 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationInput ImageThe input image file represen

Pagina 25 - Wire the Modules

Publication 1769-UM020A-EN-P - December 2009 31Module Data, Status, and Channel Configuration Chapter 3Input Data FileThe input data file lets

Pagina 26 - Terminal Layout

32 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationUnder-range (low clamp) Status Bits (U0…

Pagina 27 - Wiring Analog Outputs

Publication 1769-UM020A-EN-P - December 2009 33Module Data, Status, and Channel Configuration Chapter 3Configuration Data FileThe configuration

Pagina 28

34 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationChannel ConfigurationEach channel is ind

Pagina 29 - Configuration

Publication 1769-UM020A-EN-P - December 2009 35Module Data, Status, and Channel Configuration Chapter 3Enable/Disable Channel (EC)This configur

Pagina 30 - Configuration File

36 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationFault Mode (FM)This configuration select

Pagina 31 - Input Data File

Publication 1769-UM020A-EN-P - December 2009 37Module Data, Status, and Channel Configuration Chapter 3Clamping (limiting)Clamping limits the o

Pagina 32 - Output Data File

38 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationOutput RampingRamping limits the speed a

Pagina 33 - Configuration Data File

Publication 1769-UM020A-EN-P - December 2009 39Module Data, Status, and Channel Configuration Chapter 3This table describes how the ramp rate i

Pagina 34 - Channel Configuration

4 Publication 1769-UM020A-EN-P - December 2009Table of ContentsUnder-range (low clamp) Status Bits (U0…U3) . . . . . . . . 32Output Data File . . . .

Pagina 35 - Program Value

40 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationThe ramp rate values are entered in the

Pagina 36 - IMPORTANT

Publication 1769-UM020A-EN-P - December 2009 41Module Data, Status, and Channel Configuration Chapter 3Engineering UnitsThe value sent by the c

Pagina 37 - Clamping (limiting)

42 Publication 1769-UM020A-EN-P - December 2009Chapter 3 Module Data, Status, and Channel ConfigurationNotes:

Pagina 38 - Output Ramping

43Publication 1769-UM020A-EN-P - December 2009 43Chapter 4Module Diagnostics and TroubleshootingIntroductionSafety ConsiderationsSafety considerations

Pagina 39

44 Publication 1769-UM020A-EN-P - December 2009Chapter 4 Module Diagnostics and TroubleshootingActivate Devices When TroubleshootingWhen troubl

Pagina 40 - Data Format Selection

Publication 1769-UM020A-EN-P - December 2009 45Module Diagnostics and Troubleshooting Chapter 4Power Cycle DiagnosticsWhen you cycle power to t

Pagina 41 - Percent Range

46 Publication 1769-UM020A-EN-P - December 2009Chapter 4 Module Diagnostics and TroubleshootingModule Error Definition TableModule errors are e

Pagina 42

Publication 1769-UM020A-EN-P - December 2009 47Module Diagnostics and Troubleshooting Chapter 4Error CodesError codes can help troubleshoot you

Pagina 43 - Safety Considerations

48 Publication 1769-UM020A-EN-P - December 2009Chapter 4 Module Diagnostics and TroubleshootingInvalid Output Range SelectedThese error codes o

Pagina 44 - Safety Circuits

Publication 1769-UM020A-EN-P - December 2009 49Module Diagnostics and Troubleshooting Chapter 4Invalid Fault Value Selected(1)These error codes

Pagina 45 - Module Errors

Publication 1769-UM020A-EN-P - December 2009 5Table of ContentsAppendix ASpecificationsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - Module Error Definition

50 Publication 1769-UM020A-EN-P - December 2009Chapter 4 Module Diagnostics and TroubleshootingModule Inhibit FunctionCompactLogix controllers

Pagina 47 - Error Codes

Publication 1769-UM020A-EN-P - December 2009 51Appendix ASpecificationsIntroductionGeneral Specifications – 1769-OF4Topic PageGeneral Specifications –

Pagina 48 - Invalid Output Range Selected

52 Publication 1769-UM020A-EN-P - December 2009Appendix A SpecificationsOutput Specifications – 1769-OF4Vendor I.D. code 1Product type code 10P

Pagina 49

Publication 1769-UM020A-EN-P - December 2009 53Specifications Appendix ACertifications – 1769-OF4Replacement PartsThe module has these replacem

Pagina 50 - Automation

54 Publication 1769-UM020A-EN-P - December 2009Appendix A SpecificationsNotes:

Pagina 51 - Specifications

Publication 1769-UM020A-EN-P - December 2009 55Appendix BModule Addressing and Configuration with MicroLogix 1500 ControllerIntroductionThis appendix

Pagina 52 - Output Specifications –

56 Publication 1769-UM020A-EN-P - December 2009Appendix B Module Addressing and Configuration with MicroLogix 1500 ControllerModule Output Imag

Pagina 53 - Replacement Parts

Publication 1769-UM020A-EN-P - December 2009 57Module Addressing and Configuration with MicroLogix 1500 Controller Appendix BConfigure Analog I

Pagina 54

58 Publication 1769-UM020A-EN-P - December 2009Appendix B Module Addressing and Configuration with MicroLogix 1500 Controller4. Double-click I/

Pagina 55 - MicroLogix 1500 Controller

Publication 1769-UM020A-EN-P - December 2009 59Module Addressing and Configuration with MicroLogix 1500 Controller Appendix B7. Enter the modul

Pagina 56 - Module Configuration File

6 Publication 1769-UM020A-EN-P - December 2009Table of Contents

Pagina 57 - MicroLogix 1500 System

60 Publication 1769-UM020A-EN-P - December 2009Appendix B Module Addressing and Configuration with MicroLogix 1500 ControllerNotes:

Pagina 58

Publication 1769-UM020A-EN-P - December 2009 61Appendix CConfiguration Using the RSLogix 5000 Generic Profile for CompactLogix ControllersIntroduction

Pagina 59

62 Publication 1769-UM020A-EN-P - December 2009Appendix C Configuration Using the RSLogix 5000 Generic Profile for CompactLogix Controllers4. I

Pagina 60

Publication 1769-UM020A-EN-P - December 2009 63Configuration Using the RSLogix 5000 Generic Profile for CompactLogix Controllers Appendix C7. T

Pagina 61 - Add the Module to Your

64 Publication 1769-UM020A-EN-P - December 2009Appendix C Configuration Using the RSLogix 5000 Generic Profile for CompactLogix ControllersConf

Pagina 62 - 6. Click OK

Publication 1769-UM020A-EN-P - December 2009 65Appendix DTwo’s Complement Binary NumbersThe controller memory stores 16-bit binary numbers. Two’s comp

Pagina 63

66 Publication 1769-UM020A-EN-P - December 2009Appendix D Two’s Complement Binary NumbersNegative Decimal ValuesIn two’s complement notation, t

Pagina 64 - Configure Each I/O Module

Publication 1769-UM020A-EN-P - December 2009 67GlossaryThe following terms and abbreviations are used throughout this manual. For definitions of terms

Pagina 65 - Positive Decimal Values

68 Publication 1769-UM020A-EN-P - December 2009Glossaryfull scale range – (FSR) The difference between the maximum and minimum specified analog input

Pagina 66 - Negative Decimal Values

Publication 1769-UM020A-EN-P - December 2009 69Glossaryoverall accuracy – The worst-case deviation of the output voltage or current from the ideal ove

Pagina 67 - Glossary

7Publication 1769-UM020A-EN-P - December 2009 7PrefaceIntroductionRead this preface to familiarize yourself with the rest of the manual.About This Pub

Pagina 68 - Function

70 Publication 1769-UM020A-EN-P - December 2009GlossaryNotes:

Pagina 69

Publication 1769-UM020A-EN-P - December 2009 71IndexNumerics1769-ADNuser manual 8Aabbreviations 67alternate last statedefinition 67attenuationdefiniti

Pagina 70

72 Publication 1769-UM020A-EN-P - December 2009Indexinstallation 13-20grounding 20heat and noise considerations 15Llatch clamp status selection 37leas

Pagina 71

Publication 1769-UM020A-EN-P - December 2009 73IndexNotes:

Pagina 72

74 Publication 1769-UM020A-EN-P - December 2009IndexNotes:

Pagina 74

Publication 1769-UM020A-EN-P - December 2009 74Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Automatio

Pagina 75

8 Publication 1769-UM020A-EN-P - December 2009Preface Additional ResourcesThese documents contain additional information about control systems

Pagina 76 - Documentation Feedback

9Publication 1769-UM020A-EN-P - December 2009 9Chapter 1OverviewIntroductionModule DescriptionThe module converts digital data from controllers to pro