Module Addressing and Configuration with MicroLogix 1500 Controller Appendix B
7. Double-click the newly-added module.
8. Configure the module's input and output channels by accessing
the corresponding configuration tabs and selecting or entering
the appropriate data.
Raw configuration data can be viewed on the Generic Extra
Data Config tab.
9. When you are finished entering all of the data, click Apply and
then OK.
10. Download the project to the MicroLogix 1500 controller.