Publication 1757-IN900A-US-P - February 2000
Installation Instructions
ProcessLogix Pulse Input Module
Catalog no. 1757-PIM
This document tells you how to install the 1757-PIM (Pulse Input Module) into the
ProcessLogix™ System. For more specific information regarding the placement of
the 1757-PIM in non-redundant and redundant configurations, refer to the
ProcessLogix System Planning Guide in Knowledge Builder.
What is the Pulse Input Module?
The 1757-PIM (Pulse Input Module) is a new addition to the ProcessLogix Rack
I/O family.
The 1757-PIM is a single-wide I/O module that serves as the interface board
between the ProcessLogix controller and field transducers that provide pulse inputs.
Typically the 1757-PIM might be used to accept pulse inputs from:
tachometers, to determine required speeds of rotation for motors, fans and
pumps
flowmeters, to determine totalized process flows such as inputs to batch
dosing operations
The 1757-PIM provides up to eight input channels and two output channels. Each
of the eight channels has a 32-bit counter to perform pulse counting and frequency
calculation for signals up to 100 KHz. Six of the eight channels also have a second
32-bit timer counter for pulse period and pulse width measurements. The
remaining channels provide pulse counting and frequency calculations and have
associated outputs that can be used for fast cut-off applications. The 1757-PIM
provides channel-to-channel and terminal-to-backplane isolation.
The 1757-PIM uses the standard 36-pin terminal block and interfaces directly to
single-ended devices. The threshold level for each channel is software configurable
and selections are either LOW (approx. 3.25V typical) or HIGH (approx. 8.80V
typical) for a high-level voltage level. The 1757-PIM interfaces directly to 5 to 24V
signal values.
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - Installation Instructions

Publication 1757-IN900A-US-P - February 2000Installation InstructionsProcessLogix Pulse Input ModuleCatalog no. 1757-PIMThis document tells you how to

Pagina 2 - Important User Information

10 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000 Click OK on the configuration form to accept all configu

Pagina 3 - Installing the Module

ProcessLogix Pulse Input Module 11Publication 1757-IN900A-US-P - February 2000SpecificationsParameter SpecificationInput Channel Characteris

Pagina 4 - Configuring the Module

12 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000Parameter SpecificationVibration:Operating/Storage Vibration

Pagina 5

ProcessLogix Pulse Input Module 13Publication 1757-IN900A-US-P - February 2000European Communities (EC) Directive ComplianceIf this product

Pagina 6

14 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000CSA Hazardous Location ApprovalCSA certifies products for ge

Pagina 7

ProcessLogix Pulse Input Module 15Publication 1757-IN900A-US-P - February 2000Approbation d’utilisation dans des environnements dangereux pa

Pagina 8

Publication 1757-IN900A-US-P - February 2000 PN 957280-08 © 2000 Rockwell International Corporation. Printed in the U.S.A.Notes:

Pagina 9

2 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000Important User InformationBecause of the variety of uses for

Pagina 10 - For Technical Assistance

ProcessLogix Pulse Input Module 3Publication 1757-IN900A-US-P - February 2000Installing the ModuleFollow the procedure below to install the

Pagina 11 - Specifications

4 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000Installing the Module in the Chassis Position the module at

Pagina 12

ProcessLogix Pulse Input Module 5Publication 1757-IN900A-US-P - February 2000 Access Control Builder. Add a new 1757-PIM from the librar

Pagina 13 - Low Voltage Directive

6 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000 If desired, enter a Module Description to explain the func

Pagina 14

ProcessLogix Pulse Input Module 7Publication 1757-IN900A-US-P - February 2000 Continue with the following procedures to configure paramet

Pagina 15

8 ProcessLogix Pulse Input Module Publication 1757-IN900A-US-P - February 2000 Continue with the following procedures to configure param

Pagina 16

ProcessLogix Pulse Input Module 9Publication 1757-IN900A-US-P - February 2000 Continue with the following procedures to configure paramet

Commenti su questo manuale