Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 19
Get Started Chapter 2
See the next chapters in this manual for different security configurations.
Assign Network Settings
By default, the module is BOOTP enabled.
Choose one of the following methods to assign an IP address.
Rotary switches on the module (before you install the module)
Rockwell BOOTP/DHCP utility (available with RSLinx and
Studio 5000 software)
RSLinx software
Studio 5000 software
For information on assigning network parameters, see EtherNet/IP Network
Configuration User Manual, publication ENET-UM001
.
Change Network Settings via the Module Web Page
Choose Administrative Settings > Device Configuration > Network
Configuration. An authenticated user can modify network parameters.
IMPORTANT
Do not simply configure the initial address assigned to the module as a
static IP address. Contact your network administrator for an appropriate
static IP address.